iconGuaranteed In Stock & Intelligent Buying Advice

icon 866-266-7638

Medical Monitoring Equipment

Medical Monitoring Equipment (85 Items)

Page
per page
Set Ascending Direction
  1. DELTA 3000 DEFIB/PACER/ECG ANALYZER

    DELTA 3000 DEFIB/PACER/ECG ANALYZER

    Delta 3000 Defib/Pacer/ECG Analyzer - Defib/AED/External Pacer/Transthoracic Pacer/ECG Analyzer (3 testers in 1 Box!) Limited quantity of these units available. The Delta 3000 combines the complete testing functions of a defibrillator tester, a pacemaker analyzer, and an ECG arrhythmia simulator into one compact, lightweight, and easy to use instrument. No other instrument delivers the performance testing power of the Delta 3000. It will test all defibrillators, all external pacemakers including transcutaneous and transvenous and all ECG equipment. The built-in user selectable test loads eliminate the need to carry extra modules to test the transcutaneous pacers. The Delta 3000 delivers unsurpassed biomedical testing capabilities in one instrument. Highlights: * Compact, Lightweight and Rugged. * Simple, Menu Driven Operation. * Large, Easy to Read Display. * Simultaneous Display of All Test Measurements. * Dedicated Print key for Immediate Documentation. * RS 232 Interface. * Battery or AC Operation. Test Functions: Defibrillator Tester: Tests All Defibrillators - Semi -Automatic, Automatic, and those with Bi-Phasic Waveforms. * Measures: Energy, Peak Voltage, Peak Current, and Cardio Sync. Time. * Storage and Playback of Output Waveforms. Pacemaker Analyzer: Tests All External Pacemakers ? Transthoracic and Transvenous Pacers. * Measures: Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refractory Periods. * 50 and 60 Hz Immunity Tests. * Transthoracic Test Load: Fixed 50 Ohm or 12 User Selectable Loads to 1000-Ohms. * A / V Pacer Test Load: 500 Ohms. ECG Simulator: Tests All ECG Equipment. * 12 lead ECG. User selectable Rates and Amplitudes. * Performance Waveforms: Sine, Square, Triangle & Pulse * 12 Arrthymia Waveforms SPECIFICATIONS: Defibrillator Analyzer: Energy Measurement: Load: 50 Ohms +/- 1% Range (High): 900 Joules, Res. 1 J. Resolution: 1 Joules Range (Low): 0 ? 100 Resolution: 0.1 Joules. Accuracy: +/- 2% of the Reading Plus 1J for Hi Range or Plus 0.5J for Low Range. Maximum voltage: 5200 Maximum Current: 100 Amp (H) Sync. Time: 0-250 ms. Waveform Output: Real Time: Output1000: 1 Stored: Discharge waveform expanded 200:1 and is repeated 8 seconds. It can be viewed through the paddles and through the ECG High Level Output. Pacemaker Analyzer: Transcutaneous: Test Load: 50 Ohms (Fixed) and Variable 100 to 1000 Ohms user selectable. Current: 1 to 200 mA Accuracy: +/- 5% +. 5 mA Pulse Width: 0.5 to 80 ms. Accuracy: +/- 1% +.1 ms. Refractory: 20 ? 500 ms Accuracy: +/- 2 % or +10ms Atrial and Ventricular: Test Load: 500 Ohms +/-1% Current: 1 to 25 mA Accuracy: +/- 5% +. 5 mA. Pulse Rate: 30 to 800 ppm. Pulse Width: 0.5 to 80 ms. Accuracy: +/- 1% +.1 ms. Refractory: 20 ? 500 ms Accuracy: +/- 2 % or +10ms Immunity Test: 50/60 Hz ECG Arrhythmia Simulator: ECG: Normal Sinus Rhythm Rate: 30, 60, 90, 120, 240 BPM Performance: Sine, Square, Triangle and Pulse Rate: 0.5 1, 2, 10, 15, 20, 25, 40 Hz. Arrhythmias: VFBC, VFBF, VTAC, AFIB, PVC, PVC1, PVC2, BGY, RBB, AFIB, ATRFT, NSR. Waveform Output: 12 Lead ECG and Paddle and HI level Output Jacks. Power Requirements: Two 9-Volt Alkaline Battery or AC adapter. Dimensions: 10 x 11 x 2.25 inches (L x W x H)(25.4 x 27.9 x 5.7 cm) Weight: 4 lbs (1.9 Kg) Accessories: Standard: AC Adapter, Universal Paddle Adapter, User Manual, Shrouded Banana Plugs (set of 2), Certificate of Calibration. Optional: Carrying Case, Paddle Adapters for various manufacturers. Please call Customer Service for part numbers.

  2. ECC X-RAY PULSE COUNTER / EXPOSURE TIME METER

    ECC X-RAY PULSE COUNTER / EXPOSURE TIME METER

    ECC X-Ray Pulse Counter / Exposure Time Meter NEW" X-ray Pulse Counter Model 8700 WARRANTY: 2-year manufacturer warranty ACCESSORIES: Operator manual, Calibration Certificate TYPICAL SALES LEAD TIME: 7-10 Business days Optional Accessories: 8700CC Carrying Case for Model 8700 - Padded Cordura: $45.00 8700RS Remote Sensor allowing operation of the pulse counter up to 10 feet from the X-Ray Head. This small weighted sensor sits under x-ray head with a cable that plugs into the 8700: $70.00 8700SC Oscilloscope cable that connects "Scope" output of the model 8700 to standard BNC oscilloscope input: $30.00 DESCRIPTION The Model 8700 X-Ray Pulse Counter/ Exposure Time Meter is used to measure the time or duration of radiation output produced by a wide variety of x-ray generators. The x-ray sensor in the 8700 allows direct measurement of exposure from the x-ray head. Pulses produced by half wave and full- wave x-ray are measured as 60 or 120 pulses per second. For DC, capacitor discharge and 3-phase x-ray, the 8700 measures the exposure time in milliseconds. When testing x-ray timers and controls, the time of relay contact can be measured using the AC input feature. The Model 8700 is "self-resetting". There is no need to reset the instrument after each reading. The reading is stored after each exposure, holding until the next exposure. RECENT IMPROVEMENTS Wider Range Increased sensitivity allows use with lower power x-rays Wider dynamic range allows use with higher power x-rays More accuracy on DC/Multiphase high power x-rays Measurement ends at 70% of peak value eliminating inaccuracy due to slow tail. Periodic calibration is not needed Digital / microprocessor circuitry does not drift or lose accuracy over time. New circuitry saves production time and parts cost, allowing us to keep our competitive prices. Low power circuitry improves battery life. FEATURES Small Hand Held Size AC or DC X-Rays New High Accuracy Circuit Self Resetting Battery Operated Two Year Warranty Direct Exposure Reading or AC Input Use for Medical or Dental X-Rays Remote Sensor Option No Periodic Calibration Needed Custom Carrying Case Option Durable ABS Plastic Case TYPICAL APPLICATIONS Measurement of Exposure Quality Assurance Verification of X-ray Exposure Time Calibration of X-ray Timer Direct Measurement of Timer Accuracy Troubleshooting and Repair of x-ray SPECIFICATIONS ACCURACY AC - one count DC- 2% +/-1 millisecond SENSITIVITY X-ray input: 40kVp, 5mA at 5 cm from top surface of case, pointed to target AC Input: 90 VAC minimum RANGE 9999 Pulses 9999 Milliseconds DISPLAY 0.4" Liquid Crystal POWER Internal 9 Volt Battery Low Battery Indicator BATTERY LIFE 48 hours continuous Typically 9 months of normal use CONTROLS/ INDICATORS Three position switch Pulse Off Milliseconds 4 digit liquid crystal display 0.4" characters Low battery indicator Oscilloscope output Remote Sensor Input PHYSICAL SIZE 80 x147x 40mm 3.15 x 5.8 x1.6 inches CONNECTIONS None required for direct exposure measurement 2 tip jacks for AC input Jack for Remote Sensor Option Jack for Oscilloscope Output OPTIONAL ACCESSORIES Remote sensor with 3 meter cable Padded Cordura Carrying Case Oscilloscope Interface Cable Long Life Battery

  3. NETECH DELTA 2000 DEFIBRILLATOR ANALYZER INCLUDING AED'S

    NETECH DELTA 2000 DEFIBRILLATOR ANALYZER INCLUDING AED'S

    NETECH Delta 2000 Defibrillator Analyzer including AED's WARRANTY: One-year Manufacturer Warranty ACCESSORIES: Calibration Certificate, Operator Manual DELTA 2000 Defibrillator Analyzer DELTA 2000 is a full function defibrillator analyzer designed to test all Bi-Phasic defibrillators including semi and automated external Defibrillators (AED). The built in ECG and arrhythmia waveforms makes it easier than ever to test the new automated defibrillators. Input jack is provided for external arrhythmia waveforms. It is compact, rugged and light-weight and costs fraction of our competitions units. FEATURES: Tests Bi-Phasic Defibrillators. Tests all AEDs. Large LCD display. Compact and easy to use Built-in arrhythmia Waveforms. Built-in ECG waveform.Internal paddle adapters. Battery or AC powered.Battery or AC powered SPECIFICATIONS Energy Measurement: Load: 50 Ohms +/- 1% Resolution: High Range: 1 Joule Low Range: 0.1 Joule Accuracy: High Range: +/- 2% of Reading +/- 1 Joules Low Range: +/- 2% of Reading +/- 0.1 Joule Sync Time: 0 - 250 ms Pulse width 0 - 60 ms Waveform Simulation: ECG @ 60 BPM and 90 BPM VFIB and VTAC. External Arrhythmia input. Waveform Output/Input: ECG High Level Output. 1/4” Phone Jack External Arrhythmia input jack. 1/4” Phone Jack Real time Waveform output. 1/4” Phone Jack Defibrillator discharge waveform (expanded 200:1) is played back through the paddle and the output Phone Jack for recording. Physical: Display: 4 Digit LCD Dimensions: 10.4 x 7.2 X 4.0” Power: 9 Volt Alkaline or AC adapter Weight: 3 lbs (1.36Kg) Optional Adapters: Paddle adapter sets are available for AEDs.

  4. BIOTEK DIGITAL PRESSURE METER

    BIOTEK DIGITAL PRESSURE METER

    Biotek Digital Pressure Meter Digital Pressure Meter WARRANTY: 6 months CALIBRATION: Will come with a current calibration certificate Reliable and accurate measurement of gas or liquid pressures. The Biotek DPM Universal Pressure Meter measures positive or negative pressures. Use a single mode switch to select one of five ranges. An LCD readout displays pressures received externally from the following sources: Ophthalmologic lasers, dialysis machines, automatic tourniquets, drainage devices, IV pumps, diagnostic and surgical suction devices, ventilators, and pressure gauges. FEATURES: *Handheld use *Air and Liquid measurements *Multiple Ranges SPECIFICATIONS: Range: -700 to +800 mmHg -952 to +1088 cm H2O -374 to +428 in of H2O -13.50 to +15.0 psi -13.5 to 75.0 psi Accuracy: +/- 1 % of full scale Pressure Connector: Male luer lock Overpressure Protection: 110psi Power: 9 V alkaline battery Dimensions: 5.75" L x 3.125" W x 2.5" H (15cm L x 8cm W x 6cm H) Weight: 10.4oz (295g)

  5. GE COROMETRICS 2120 IS SERIES FETAL/MATERNAL MONITOR SYSTEM

    GE COROMETRICS 2120 IS SERIES FETAL/MATERNAL MONITOR SYSTEM

    GE Corometrics 2120 is Series Fetal/Maternal Monitor System Complete System with 17" Monitor, keyboard, mouse, 2 ultrasound transducers, 1 toco transducer (ALL NEW!) MECG Cable/Leads, SPo2 Interface Cable/Sensor, NIBP Hose/Adult Cuff. Comprehensive perinatal information at your fingertips Both powerful and flexible, the advanced Corometrics ® 2120is Series monitor captures fetal heart rate and uterine activity, and gives the option to document maternal vital signs at the same time. • Integrated Solution: Multi-device integration streamlines workflow ? replaces numerous stand-alone devices with one comprehensive, convenient system. • Inter-bed Surveillance: Bed-to-bed connectivity enhances vigilance and coverage ? caregivers can easily observe any patient from any bedside without central station support. • Information System: Access the complete patient record more conveniently and cost-effectively ? single-pane-of-glass interface to both monitoring and Centricity Perinatal CIS functions. Designed to address every monitoring need, the system is compact and easy to use. And, by eliminating the need for additional external devices, the 2120is Series helps you cost-effectively deliver uncompromising maternal/fetal monitoring care. Call for more info.