DELTA 3000 DEFIB/PACER/ECG ANALYZER
- Product SKU: WB428
- Product Name: DELTA 3000 DEFIB/PACER/ECG ANALYZER
- Manufacturer: -ASSORTED
Delta 3000 Defib/Pacer/ECG Analyzer - Defib/AED/External Pacer/Transthoracic Pacer/ECG Analyzer (3 testers in 1 Box!) Limited quantity of these units available. The Delta 3000 combines the complete testing functions of a defibrillator tester, a pacemaker analyzer, and an ECG arrhythmia simulator into one compact, lightweight, and easy to use instrument. No other instrument delivers the performance testing power of the Delta 3000. It will test all defibrillators, all external pacemakers including transcutaneous and transvenous and all ECG equipment. The built-in user selectable test loads eliminate the need to carry extra modules to test the transcutaneous pacers. The Delta 3000 delivers unsurpassed biomedical testing capabilities in one instrument. Highlights: * Compact, Lightweight and Rugged. * Simple, Menu Driven Operation. * Large, Easy to Read Display. * Simultaneous Display of All Test Measurements. * Dedicated Print key for Immediate Documentation. * RS 232 Interface. * Battery or AC Operation. Test Functions: Defibrillator Tester: Tests All Defibrillators - Semi -Automatic, Automatic, and those with Bi-Phasic Waveforms. * Measures: Energy, Peak Voltage, Peak Current, and Cardio Sync. Time. * Storage and Playback of Output Waveforms. Pacemaker Analyzer: Tests All External Pacemakers ? Transthoracic and Transvenous Pacers. * Measures: Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refractory Periods. * 50 and 60 Hz Immunity Tests. * Transthoracic Test Load: Fixed 50 Ohm or 12 User Selectable Loads to 1000-Ohms. * A / V Pacer Test Load: 500 Ohms. ECG Simulator: Tests All ECG Equipment. * 12 lead ECG. User selectable Rates and Amplitudes. * Performance Waveforms: Sine, Square, Triangle & Pulse * 12 Arrthymia Waveforms SPECIFICATIONS: Defibrillator Analyzer: Energy Measurement: Load: 50 Ohms +/- 1% Range (High): 900 Joules, Res. 1 J. Resolution: 1 Joules Range (Low): 0 ? 100 Resolution: 0.1 Joules. Accuracy: +/- 2% of the Reading Plus 1J for Hi Range or Plus 0.5J for Low Range. Maximum voltage: 5200 Maximum Current: 100 Amp (H) Sync. Time: 0-250 ms. Waveform Output: Real Time: Output1000: 1 Stored: Discharge waveform expanded 200:1 and is repeated 8 seconds. It can be viewed through the paddles and through the ECG High Level Output. Pacemaker Analyzer: Transcutaneous: Test Load: 50 Ohms (Fixed) and Variable 100 to 1000 Ohms user selectable. Current: 1 to 200 mA Accuracy: +/- 5% +. 5 mA Pulse Width: 0.5 to 80 ms. Accuracy: +/- 1% +.1 ms. Refractory: 20 ? 500 ms Accuracy: +/- 2 % or +10ms Atrial and Ventricular: Test Load: 500 Ohms +/-1% Current: 1 to 25 mA Accuracy: +/- 5% +. 5 mA. Pulse Rate: 30 to 800 ppm. Pulse Width: 0.5 to 80 ms. Accuracy: +/- 1% +.1 ms. Refractory: 20 ? 500 ms Accuracy: +/- 2 % or +10ms Immunity Test: 50/60 Hz ECG Arrhythmia Simulator: ECG: Normal Sinus Rhythm Rate: 30, 60, 90, 120, 240 BPM Performance: Sine, Square, Triangle and Pulse Rate: 0.5 1, 2, 10, 15, 20, 25, 40 Hz. Arrhythmias: VFBC, VFBF, VTAC, AFIB, PVC, PVC1, PVC2, BGY, RBB, AFIB, ATRFT, NSR. Waveform Output: 12 Lead ECG and Paddle and HI level Output Jacks. Power Requirements: Two 9-Volt Alkaline Battery or AC adapter. Dimensions: 10 x 11 x 2.25 inches (L x W x H)(25.4 x 27.9 x 5.7 cm) Weight: 4 lbs (1.9 Kg) Accessories: Standard: AC Adapter, Universal Paddle Adapter, User Manual, Shrouded Banana Plugs (set of 2), Certificate of Calibration. Optional: Carrying Case, Paddle Adapters for various manufacturers. Please call Customer Service for part numbers.
- Product Availability: Available
How can I help you?
Hi, I'm Marshall Duskes. Click on , pick up the phone, or use one of the other platforms here to get in touch with me about this product.
Toll Free:866-266-7638
International:514-619-6981
- Product SKU: WB428
- Product Name: DELTA 3000 DEFIB/PACER/ECG ANALYZER
- Manufacturer: -ASSORTED
Delta 3000 Defib/Pacer/ECG Analyzer - Defib/AED/External Pacer/Transthoracic Pacer/ECG Analyzer (3 testers in 1 Box!) Limited quantity of these units available. The Delta 3000 combines the complete testing functions of a defibrillator tester, a pacemaker analyzer, and an ECG arrhythmia simulator into one compact, lightweight, and easy to use instrument. No other instrument delivers the performance testing power of the Delta 3000. It will test all defibrillators, all external pacemakers including transcutaneous and transvenous and all ECG equipment. The built-in user selectable test loads eliminate the need to carry extra modules to test the transcutaneous pacers. The Delta 3000 delivers unsurpassed biomedical testing capabilities in one instrument. Highlights: * Compact, Lightweight and Rugged. * Simple, Menu Driven Operation. * Large, Easy to Read Display. * Simultaneous Display of All Test Measurements. * Dedicated Print key for Immediate Documentation. * RS 232 Interface. * Battery or AC Operation. Test Functions: Defibrillator Tester: Tests All Defibrillators - Semi -Automatic, Automatic, and those with Bi-Phasic Waveforms. * Measures: Energy, Peak Voltage, Peak Current, and Cardio Sync. Time. * Storage and Playback of Output Waveforms. Pacemaker Analyzer: Tests All External Pacemakers ? Transthoracic and Transvenous Pacers. * Measures: Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refractory Periods. * 50 and 60 Hz Immunity Tests. * Transthoracic Test Load: Fixed 50 Ohm or 12 User Selectable Loads to 1000-Ohms. * A / V Pacer Test Load: 500 Ohms. ECG Simulator: Tests All ECG Equipment. * 12 lead ECG. User selectable Rates and Amplitudes. * Performance Waveforms: Sine, Square, Triangle & Pulse * 12 Arrthymia Waveforms SPECIFICATIONS: Defibrillator Analyzer: Energy Measurement: Load: 50 Ohms +/- 1% Range (High): 900 Joules, Res. 1 J. Resolution: 1 Joules Range (Low): 0 ? 100 Resolution: 0.1 Joules. Accuracy: +/- 2% of the Reading Plus 1J for Hi Range or Plus 0.5J for Low Range. Maximum voltage: 5200 Maximum Current: 100 Amp (H) Sync. Time: 0-250 ms. Waveform Output: Real Time: Output1000: 1 Stored: Discharge waveform expanded 200:1 and is repeated 8 seconds. It can be viewed through the paddles and through the ECG High Level Output. Pacemaker Analyzer: Transcutaneous: Test Load: 50 Ohms (Fixed) and Variable 100 to 1000 Ohms user selectable. Current: 1 to 200 mA Accuracy: +/- 5% +. 5 mA Pulse Width: 0.5 to 80 ms. Accuracy: +/- 1% +.1 ms. Refractory: 20 ? 500 ms Accuracy: +/- 2 % or +10ms Atrial and Ventricular: Test Load: 500 Ohms +/-1% Current: 1 to 25 mA Accuracy: +/- 5% +. 5 mA. Pulse Rate: 30 to 800 ppm. Pulse Width: 0.5 to 80 ms. Accuracy: +/- 1% +.1 ms. Refractory: 20 ? 500 ms Accuracy: +/- 2 % or +10ms Immunity Test: 50/60 Hz ECG Arrhythmia Simulator: ECG: Normal Sinus Rhythm Rate: 30, 60, 90, 120, 240 BPM Performance: Sine, Square, Triangle and Pulse Rate: 0.5 1, 2, 10, 15, 20, 25, 40 Hz. Arrhythmias: VFBC, VFBF, VTAC, AFIB, PVC, PVC1, PVC2, BGY, RBB, AFIB, ATRFT, NSR. Waveform Output: 12 Lead ECG and Paddle and HI level Output Jacks. Power Requirements: Two 9-Volt Alkaline Battery or AC adapter. Dimensions: 10 x 11 x 2.25 inches (L x W x H)(25.4 x 27.9 x 5.7 cm) Weight: 4 lbs (1.9 Kg) Accessories: Standard: AC Adapter, Universal Paddle Adapter, User Manual, Shrouded Banana Plugs (set of 2), Certificate of Calibration. Optional: Carrying Case, Paddle Adapters for various manufacturers. Please call Customer Service for part numbers.