Medical Imaging Equipment
-
ATL HDI COLOR DOPPLER ULTRASOUND UNIT MODEL: 3000
ATL HDI color doppler ultrasound unit model 3000. Software VER 47.18 cardiac/vascular calc. package. Transducer: cardiac P3-2.4 THRU 2.0 MHZ (broadband intercostal probe) / vascular:L7-4 THRU 4.0 MHZ (vascular/small parts linear) unit completely refurbished. We have 2 units available.
-
ATL HDI COLOR DOPPLER ULTRASOUND UNIT MODEL: 3000
General Electric X-Ray Model: AMX4 in good operationg condition complete set of batteries installed in April of 2007. Calibration was done in April. It looks like it was manufactured in 1988
-
COMPLETE ACUSON CARDIO/ VASCULAR ULTRASOUND SYSTEM
Complete Acuson cardio/ vascular ultrasound system.
-
ACUSAN ULTRASOUND MODEL: ASPEN.
Acusan Ultrasound Model: ASPEN. The new golden standard in echocardiography is defined by native tissue harmonic imaging (NTHI) and delta differential echo amplification--two powerfull technologies that were first introduced on Acuson's Sequoia echocardiography system. Now they migrated to the advanced system
-
ULTRASOUND POWER METER UPM DT100AV
Ultrasound Power Meter UPM DT100AV **New** All products manufactured by Ohmic Co. are warranted to be free of defects in material and workmanship for one year after delivery. Any equipment found to be defective within this period will be repaired or replaced free of charge. Specifications: Power Range: 0.1 to 30 Watts Resolution: +/-200 mW, +/- 0.01gram, +/-1 count Display: 3-digit LCD, 1.3" H Operating Temp: 10-40 degrees C Accuracy: +/-3% @ 10 Watts Stabilization: 2.5 Second Integration Maximum Weight Capacity: 410 Grams Maximum Transducer Size: 3" Diameter Transducer Operating Frequency: 1-10MHz Test Media: Degassed Water Data Output: Bi-Directional RS-232 Power: 12Vac, 1 Amp 120VAC Adaptor Supplied(adaptors for 240vac available on special order: 120vac to 12vac EMI Rating: Conforms to CE Electrical Safety: Conforms to CSA Size: 8"H x 12" L x 8.75" W Weight: 11 Lbs Net Carrying Case: Black Anodized Aluminum
-
ULTRASOUND POWER METER UPM DT100AV
Ultrasound Power Meter UPM DT100AV Specifications: Power Range: 0.1 to 30 Watts Resolution: +/-200 mW, +/- 0.01gram, +/-1 count Display: 3-digit LCD, 1.3" H Operating Temp: 10-40 degrees C Accuracy: +/-3% @ 10 Watts Stabilization: 2.5 Second Integration Maximum Weight Capacity: 410 Grams Maximum Transducer Size: 3" Diameter Transducer Operating Frequency: 1-10MHz Test Media: Degassed Water Data Output: Bi-Directional RS-232 Power: 12Vac, 1 Amp 120VAC Adaptor Supplied(adaptors for 240vac available on special order: 120vac to 12vac EMI Rating: Conforms to CE Electrical Safety: Conforms to CSA Size: 8"H x 12" L x 8.75" W Weight: 11 Lbs Net Carrying Case: Black Anodized Aluminum
-
Ultrasound Power Meter UPM-30 Specifications: Power Range: 150mW to 30 Watts Resolution: +/-150mW Minimum Detectable Power Level: +/- 150mW Minimum Accuracy: +/-5% Maximum Accuracy: +/-4% Test Media: Degassed, distilled water at room temperature. Test Tank Liquid Capacity: 1,350ml Test Tank Lining: 0.5" (12.7mm) neoprene rubber Test Tank Dimensions: Outside: 5.75" (146mm)dia. x 5.55" (140mm) Inside: 4.5" (114mm) dia. x 5.25" (133mm) Cone Target: 3.5" (89mm) dia. x 2" (51mm) height Power: Not Required EMI Rating: Conforms to CE Electrical Safety: Conforms to CSA Size: 8"H x 12" L x 8.75" W Weight: 18 Lbs Net Carrying Case: Black Anodized Aluminum
-
ULTRASOUND POWER METER UPM-DT-10AV
Ultrasound Power Meter UPM-DT-10AV Specifications: Measurement Range: 0-30 Watts Resolution: +/-2 mW Minimum Detectable Power: 1mW Display Sensitivity: 0.001/0.01/0.1 Watt Accuracy: +/-3% + One Digit Zeroing Method: Automatic Averaging of Measured Values: 100 Stabilization: 2.5 Second Integration Maximum Weight Capacity: 210 Grams Maximum Transducer Size: 3" Diameter Transducer Operating Frequency: .5-10MHz Test Media: Degassed Water Computer Interface: RS-232, 300-9600 Baud Default Baud Rate: 2400 Power: 12Vac, 1 Amp 120VAC Adaptor Supplied(adaptors for 240vac available on special order: 120vac to 12vac EMI Rating: Conforms to CE &FCC Electrical Safety: Conforms to UL &CSA Size: 11"H x 15" L x 10" W Weight: 22 Lbs Net Carrying Case: Black Anodized Aluminum
-
NETECH UPM 2000 ULTRASOUND POWER METER
Accessories: AC Adapter, Carrying Case, Calibration Weight, Probe clamp assembly GENERAL INFORMATION: The UPM 2000 Digital Ultrasound Wattmeter (Power meter) is deigned to provide an accurate means of verifying and calibrating the output of therapeutic ultrasound devices. It measures output utilizing state of the art microprocessor and strain gauge bridge transducer, provides quick reading The UPM 2000 is compact, simple to use, portable and rugged built. The UPM 2000 uses an auto zero function and a calibration check weight provided with the unit making it easy to verify the calibration in the field. The unit is powered by a 9 Volt alkaline or using AC adapter supplied with the unit. FEATURES: Measures total-pulsed or continuous-average power Quickly and accurately make power measurements Accommodate a variety of transducer shapes and sizes Large easy to read Display High Resolution -0.1W Easy drainage of the tank Auto zero function RS 232 Port Light weight and easy to carry Field Calibration check using weight standard. Compact, light weight, easy to carry SPECIFICATIONS: Measurement range : 0.1 to 30 Watts Input Power Level: 0 - 30 W Input Frequency: 0.5 - 10 MHz Resolution: 0.1 W Accuracy: Electrical +/- .15 W (+/-.01 grams) Repeatability: +/- 3% of reading +/- .2 watts Acceptable Transducer Size: 3 max (7.6 cm) diameter Operating Temperature: 10 degree - 30 degree C (50 degree - 85 degree F) Power requirements: 9 Volt alkaline or equivalent Battery life: 10 Hours continuous operation Dimensions: 9 x 14 1/2 Height: 7 1/2 (10 3/4 with Clamp Post)
-
Datascope System 95 Intra-aortic Balloon Pump Accessories: ECG Cable/Leads, BP Cable, Power Cord, Permantly attached Doppler, Condition: Patient Ready FEATURES: Intra-Aortic Balloon Pump ECG Triggers Pacer Triggers Advanced pneumatic design Permanently attached doppler Detailed monitoring Rotating monitor SPECIFICATIONS: Annotations: ECG: Lead Pressure: Scale Parameters: heart rate, systolic, diastolic, mean, augmented pressure Trend: Same as trend display Recording Format: Recorder: thermal array type recorder/2" thermal paper Waveform Presentation: ECG, arterial pressure, optional balloon pressure waveform. Graphic Presentation: heart rate trend, pressure trends. Vent marker: trigger point, Inflate interval Trend Display: Memory: 8 hours total; 30 minutes of 5 minutes average; 7.5 hours of 15 minutes average. Data Available: heart rate, peak systolic, pressure, diastolic pressure, mean and augmented pressure Inputs/Outputs: ECG Connectors: 6 pin 5-lead AAMI proposed standard; patient input 3-conductor phone jacks; monitor level. Pressure Connectors: 6-pin male connector, Datascope-specified compatible transducer; 3-conductor phone jack; monitor level Voltage Interface: ECG=1V/mV nominal arterial pressure=1V/100mmHG nominal Pressure: Pressure sensitivity to trigger: 15 mmHg min pulse amplitude Transducer Requirements: ? Sensitivity: 5.0microV/V/mmHG. ? Excitation: +5V DC.? ? Zero Range: +/-120mmHg Trigger Source: ECG trigger requirement: 120microV +/- 20microV/40microV at max. gain. Pacer Rejection: (no tails): +/- 2mV to +/- 700mV duration 0.1 ms to 2 ms. Pressure: adjustable between 7 mmHg to 30 mmHg pulse amplitude. Pacer A-V: A-V interval 80-225 ms rate or equal to 125bpm. Pacer A: trigger requirement (same as ECG). Pacer V: 185bpm. Internal: 40-120 in 5bpm increments; default rate 80 +/- 1 bpm ESIS: automatic suppression with internal ECG amplifier ECG: Leads: I, II, III, avr, avl, avf, V Frequency Response: 0.5 - 135 Hz output jack 0.5 - 12 Hz display Leakage Current: 10microA source current, 20microA sink current. Defibrillation Protection: discharge levels up to 500 joules. Recovery Time: trace returns to screen, 2 sec. maximum Display: Type: Gas Plasma, 5.2" x 8.25", 132mm x 210mm. Channels: ECG, Arterial Pressure, Optional balloon pressure waveform Reference Line: 0-300 mmHg/max Pneumatics: System Compressor: Dual head diaphragm pump brushless DC motor. Patient Balloon Pump Gas: Medical-Grade Helium Blood Detection: Automatic protection of pneumatics by optical detection and isolation of blood in auto fill lint. Electrical: Battery Pack: 24VDC, 18AH Type: Sealed Lead Acid, maintenance free Battery Operating Time: 1.5 hours@150bpm. Battery Recharge Time: 18 hours maximum from completely discharged to full. AC Power Requirements: 500 VA normal, 90-130V, 50/60Hz; 200-260, 50-60Hz Mechanical: Dimensions: 48" H x 33" W x 19" D (104cm x 71cm x 61 cm) Weight: 175lbs (80kg) without helium tank.
-
ULTRASOUND POWER METER UPM-DT-10AV
Ultrasound Power Meter UPM-DT-10AV Specifications: Power Range: 0-30 Watts Resolution: 2 or 20mw (1.5 or 15mW in grams mode) Minimum Detectable Power: 10mW Display Sensitivity: 0.01/0.1/1 Watt Accuracy: +/-3% + One Digit Zeroing Method: Automatic Averaging of Measured Values: 100 Stabilization: 2.5 Second Integration Maximum Weight Capacity: 600 Grams Maximum Transducer Size: 3" Diameter Transducer Operating Frequency: .5-10MHz Test Media: Degassed Water Computer Interface: RS-232, 300-9600 Baud Default Baud Rate: 2400 Power: 12Vac, 1 Amp 120VAC Adaptor Supplied(adaptors for 240vac available on special order: 120vac to 12vac EMI Rating: Conforms to CE &FCC Electrical Safety: Conforms to UL &CSA Size: 11"H x 15" L x 10" W Weight: 22 Lbs Net Carrying Case: Black Anodized Aluminum
-
SIEMENS MRI EQUIPMENT AVAILALBE
Call Marshall Duskes for your Siemens MRI (Magnetic Resonance Imaging) Equipment requirements. SOMATOMEMOTION, SCANNERS, MRI COILS, etc...... 450-902-0489.
-
We can supply Philips Medical Equipment. Items such as: DEFIBRILLATOR-MONITORS, PAGEWRITER EKG RECORDER, DIAGNOST 94 remote control system, CT SCanners (ACQSIM SINGLE SLICE WIDE BORE), General Exam Room Equipment, X-Ray equipment, and a host of other Philips Medical Grade Equipment. Please send your inquiries to Marshall today. 450-902-0489.
-
PHILIPS SONOS 5500 ULTRASOUND M2424A S/N US97805466
Philips Sonos 5500 Ultrasound m2424a s/n US97805466. ABA K01 A05 C09 Probes: S3 Model 21311A s/n US00325756 T-Probe 21221 A Hewlett Packard. Unit is used and in good working condition.
-
Ultrasound scanners by GE and Toshiba. POR. - GE Vivid I from 2008, Cardio/vascular. Options: CardiacApp, EchoPac, PWD, CWD, CFM. Probe: 3S-RS. - GE LogiqBook XP from 2006, Radiology. Options: Basic, Colorflow & Doppler. Probes: 3C-RS convex. 8L-RS linear. - GE Logiq 5 from 2003. Options: Basic, Dicom, Easy 3D. Probe: 3,5C Convex. - GE Logiq 9 expert from 2002, BT02. Options: Dicom. Probes: 3,5C Convex. M12L Linear. - Toshiba SSA-660A Xario from 2005, Not CE market, Pvt-375BTconvex, PLT-1204AT linear.
-
ULTRASOUND PROBES BY ACUSON, SIEMENS AND MORE
Large inventory of ultrasound probes by Acuson, Siemens, BK, SonoSite and GE. Click "more info" for complete listing of models available.
-
ULTRASONIX CEP ULTRASOUND SYSTEM
One 2008 Ultrasonix CEP ultrasound system available. Spec: single monitor, color doppler, DICOM. Software version Sonix 3.0.6. Transducers: 4-2, 5-2, 15-5, all functioning. Software & manuals included.
-
DENTIMAX #2 DIGITAL MOTION X-RAY
Dentimax sensor imaging system, complete #2 digital motion x-ray.
-
MEDICAL SCIENTIFIC SUPPLIES & EQUIPMENT
Medical equipment and supplies such as central station monitor transmitters, infusion pumps, module racks and anesthesia monitors by such manufacturers as Agilent, Baxter, Datascope, Philips and more. Click "more info" for complete list.





