iconGuaranteed In Stock & Intelligent Buying Advice

icon 866-266-7638

DATASCOPE SYSTEM 95

Datascope System 95 Intra-aortic Balloon Pump Accessories: ECG Cable/Leads, BP Cable, Power Cord...
Read More
  • Product SKU: WB483
  • Product Name: DATASCOPE SYSTEM 95
  • Manufacturer: -ASSORTED
Description:

Datascope System 95 Intra-aortic Balloon Pump Accessories: ECG Cable/Leads, BP Cable, Power Cord, Permantly attached Doppler, Condition: Patient Ready FEATURES: Intra-Aortic Balloon Pump ECG Triggers Pacer Triggers Advanced pneumatic design Permanently attached doppler Detailed monitoring Rotating monitor SPECIFICATIONS: Annotations: ECG: Lead Pressure: Scale Parameters: heart rate, systolic, diastolic, mean, augmented pressure Trend: Same as trend display Recording Format: Recorder: thermal array type recorder/2" thermal paper Waveform Presentation: ECG, arterial pressure, optional balloon pressure waveform. Graphic Presentation: heart rate trend, pressure trends. Vent marker: trigger point, Inflate interval Trend Display: Memory: 8 hours total; 30 minutes of 5 minutes average; 7.5 hours of 15 minutes average. Data Available: heart rate, peak systolic, pressure, diastolic pressure, mean and augmented pressure Inputs/Outputs: ECG Connectors: 6 pin 5-lead AAMI proposed standard; patient input 3-conductor phone jacks; monitor level. Pressure Connectors: 6-pin male connector, Datascope-specified compatible transducer; 3-conductor phone jack; monitor level Voltage Interface: ECG=1V/mV nominal arterial pressure=1V/100mmHG nominal Pressure: Pressure sensitivity to trigger: 15 mmHg min pulse amplitude Transducer Requirements: ? Sensitivity: 5.0microV/V/mmHG. ? Excitation: +5V DC.? ? Zero Range: +/-120mmHg Trigger Source: ECG trigger requirement: 120microV +/- 20microV/40microV at max. gain. Pacer Rejection: (no tails): +/- 2mV to +/- 700mV duration 0.1 ms to 2 ms. Pressure: adjustable between 7 mmHg to 30 mmHg pulse amplitude. Pacer A-V: A-V interval 80-225 ms rate < or equal to 125bpm. Pacer A: trigger requirement (same as ECG). Pacer V: <185bpm. Internal: 40-120 in 5bpm increments; default rate 80 +/- 1 bpm ESIS: automatic suppression with internal ECG amplifier ECG: Leads: I, II, III, avr, avl, avf, V Frequency Response: 0.5 - 135 Hz output jack 0.5 - 12 Hz display Leakage Current: <10microA source current, <20microA sink current. Defibrillation Protection: discharge levels up to 500 joules. Recovery Time: trace returns to screen, 2 sec. maximum Display: Type: Gas Plasma, 5.2" x 8.25", 132mm x 210mm. Channels: ECG, Arterial Pressure, Optional balloon pressure waveform Reference Line: 0-300 mmHg/max Pneumatics: System Compressor: Dual head diaphragm pump brushless DC motor. Patient Balloon Pump Gas: Medical-Grade Helium Blood Detection: Automatic protection of pneumatics by optical detection and isolation of blood in auto fill lint. Electrical: Battery Pack: 24VDC, 18AH Type: Sealed Lead Acid, maintenance free Battery Operating Time: 1.5 hours@150bpm. Battery Recharge Time: 18 hours maximum from completely discharged to full. AC Power Requirements: 500 VA normal, 90-130V, 50/60Hz; 200-260, 50-60Hz Mechanical: Dimensions: 48" H x 33" W x 19" D (104cm x 71cm x 61 cm) Weight: 175lbs (80kg) without helium tank.

  • Product Availability: Available
SKU
WB483

Read Our Reviews

4.4
Based on 2714 reviews from certified buyers.
  • Nice people

    Satisfied even with their no refund policy.

    By Charles Kayne on

  • Will recommend you

    These guys managed to send me the order in 3 different packages for a better shipping quote.

    By Robert Gardner on

  • Amazing inventory

    Surplustraders and the people behind it is what really makes the industry go forward..

    By Jamie Wilson on

image

How can I help you?

Hi, I'm Marshall Duskes. Click on , pick up the phone, or use one of the other platforms here to get in touch with me about this product.

Toll Free:866-266-7638

International:514-619-6981

Datascope System 95 Intra-aortic Balloon Pump Accessories: ECG Cable/Leads, BP Cable, Power Cord, Permantly attached Doppler, Condition: Patient Ready FEATURES: Intra-Aortic Balloon Pump ECG Triggers Pacer Triggers Advanced pneumatic design Permanently attached doppler Detailed monitoring Rotating monitor SPECIFICATIONS: Annotations: ECG: Lead Pressure: Scale Parameters: heart rate, systolic, diastolic, mean, augmented pressure Trend: Same as trend display Recording Format: Recorder: thermal array type recorder/2" thermal paper Waveform Presentation: ECG, arterial pressure, optional balloon pressure waveform. Graphic Presentation: heart rate trend, pressure trends. Vent marker: trigger point, Inflate interval Trend Display: Memory: 8 hours total; 30 minutes of 5 minutes average; 7.5 hours of 15 minutes average. Data Available: heart rate, peak systolic, pressure, diastolic pressure, mean and augmented pressure Inputs/Outputs: ECG Connectors: 6 pin 5-lead AAMI proposed standard; patient input 3-conductor phone jacks; monitor level. Pressure Connectors: 6-pin male connector, Datascope-specified compatible transducer; 3-conductor phone jack; monitor level Voltage Interface: ECG=1V/mV nominal arterial pressure=1V/100mmHG nominal Pressure: Pressure sensitivity to trigger: 15 mmHg min pulse amplitude Transducer Requirements: ? Sensitivity: 5.0microV/V/mmHG. ? Excitation: +5V DC.? ? Zero Range: +/-120mmHg Trigger Source: ECG trigger requirement: 120microV +/- 20microV/40microV at max. gain. Pacer Rejection: (no tails): +/- 2mV to +/- 700mV duration 0.1 ms to 2 ms. Pressure: adjustable between 7 mmHg to 30 mmHg pulse amplitude. Pacer A-V: A-V interval 80-225 ms rate < or equal to 125bpm. Pacer A: trigger requirement (same as ECG). Pacer V: <185bpm. Internal: 40-120 in 5bpm increments; default rate 80 +/- 1 bpm ESIS: automatic suppression with internal ECG amplifier ECG: Leads: I, II, III, avr, avl, avf, V Frequency Response: 0.5 - 135 Hz output jack 0.5 - 12 Hz display Leakage Current: <10microA source current, <20microA sink current. Defibrillation Protection: discharge levels up to 500 joules. Recovery Time: trace returns to screen, 2 sec. maximum Display: Type: Gas Plasma, 5.2" x 8.25", 132mm x 210mm. Channels: ECG, Arterial Pressure, Optional balloon pressure waveform Reference Line: 0-300 mmHg/max Pneumatics: System Compressor: Dual head diaphragm pump brushless DC motor. Patient Balloon Pump Gas: Medical-Grade Helium Blood Detection: Automatic protection of pneumatics by optical detection and isolation of blood in auto fill lint. Electrical: Battery Pack: 24VDC, 18AH Type: Sealed Lead Acid, maintenance free Battery Operating Time: 1.5 hours@150bpm. Battery Recharge Time: 18 hours maximum from completely discharged to full. AC Power Requirements: 500 VA normal, 90-130V, 50/60Hz; 200-260, 50-60Hz Mechanical: Dimensions: 48" H x 33" W x 19" D (104cm x 71cm x 61 cm) Weight: 175lbs (80kg) without helium tank.
  • Product SKU: WB483
  • Product Name: DATASCOPE SYSTEM 95
  • Manufacturer: -ASSORTED
Description:

Datascope System 95 Intra-aortic Balloon Pump Accessories: ECG Cable/Leads, BP Cable, Power Cord, Permantly attached Doppler, Condition: Patient Ready FEATURES: Intra-Aortic Balloon Pump ECG Triggers Pacer Triggers Advanced pneumatic design Permanently attached doppler Detailed monitoring Rotating monitor SPECIFICATIONS: Annotations: ECG: Lead Pressure: Scale Parameters: heart rate, systolic, diastolic, mean, augmented pressure Trend: Same as trend display Recording Format: Recorder: thermal array type recorder/2" thermal paper Waveform Presentation: ECG, arterial pressure, optional balloon pressure waveform. Graphic Presentation: heart rate trend, pressure trends. Vent marker: trigger point, Inflate interval Trend Display: Memory: 8 hours total; 30 minutes of 5 minutes average; 7.5 hours of 15 minutes average. Data Available: heart rate, peak systolic, pressure, diastolic pressure, mean and augmented pressure Inputs/Outputs: ECG Connectors: 6 pin 5-lead AAMI proposed standard; patient input 3-conductor phone jacks; monitor level. Pressure Connectors: 6-pin male connector, Datascope-specified compatible transducer; 3-conductor phone jack; monitor level Voltage Interface: ECG=1V/mV nominal arterial pressure=1V/100mmHG nominal Pressure: Pressure sensitivity to trigger: 15 mmHg min pulse amplitude Transducer Requirements: ? Sensitivity: 5.0microV/V/mmHG. ? Excitation: +5V DC.? ? Zero Range: +/-120mmHg Trigger Source: ECG trigger requirement: 120microV +/- 20microV/40microV at max. gain. Pacer Rejection: (no tails): +/- 2mV to +/- 700mV duration 0.1 ms to 2 ms. Pressure: adjustable between 7 mmHg to 30 mmHg pulse amplitude. Pacer A-V: A-V interval 80-225 ms rate < or equal to 125bpm. Pacer A: trigger requirement (same as ECG). Pacer V: <185bpm. Internal: 40-120 in 5bpm increments; default rate 80 +/- 1 bpm ESIS: automatic suppression with internal ECG amplifier ECG: Leads: I, II, III, avr, avl, avf, V Frequency Response: 0.5 - 135 Hz output jack 0.5 - 12 Hz display Leakage Current: <10microA source current, <20microA sink current. Defibrillation Protection: discharge levels up to 500 joules. Recovery Time: trace returns to screen, 2 sec. maximum Display: Type: Gas Plasma, 5.2" x 8.25", 132mm x 210mm. Channels: ECG, Arterial Pressure, Optional balloon pressure waveform Reference Line: 0-300 mmHg/max Pneumatics: System Compressor: Dual head diaphragm pump brushless DC motor. Patient Balloon Pump Gas: Medical-Grade Helium Blood Detection: Automatic protection of pneumatics by optical detection and isolation of blood in auto fill lint. Electrical: Battery Pack: 24VDC, 18AH Type: Sealed Lead Acid, maintenance free Battery Operating Time: 1.5 hours@150bpm. Battery Recharge Time: 18 hours maximum from completely discharged to full. AC Power Requirements: 500 VA normal, 90-130V, 50/60Hz; 200-260, 50-60Hz Mechanical: Dimensions: 48" H x 33" W x 19" D (104cm x 71cm x 61 cm) Weight: 175lbs (80kg) without helium tank.

Is Your Equipment Broken?

Utilize Service and Maintenance Expertise with Surplus Traders:

When in need of service and repair for your equipment, make Surplus Traders your initial point of contact. While discarding the item might be a consideration, our cost-effective repair and maintenance services can swiftly restore your product to optimal functionality, akin to its original state. This approach allows you to economize both in terms of finances and time. Additionally, you avoid the hassle of sourcing compatible and pricey replacements for your system. At Surplus Traders, we conduct repairs using genuine OEM parts, ensuring a restoration process that guarantees 100% uptime for your equipment. We boast a team of certified repair technicians with comprehensive expertise in servicing a diverse range of equipment and devices available in the market. We emphasize the preservation and repair of equipment to minimize waste and support sustainable practices. Do not discard your equipment hastily. Reach out to our dedicated equipment hotline today to obtain a quote for any required service and maintenance. Surplus Traders provides flat-rate repair services for Barcode and Point of Sale (POS) equipment, as well as various other digital and industrial machinery. Furthermore, we offer flexible repair and maintenance contracts spanning 1, 2, or 3 years, featuring rapid turnaround times to suit your requirements. In summary, instead of prematurely disposing of your equipment, contact Surplus Traders today to benefit from our expertise and commitment to efficient repairs.

Reach us at 1-866-266-7638 or via email at repairs@surplustraders.net