EATON POW-R-LINE SWITCHBOARD 120/240V, 60HZ, 1PH-3WIRE - NEVER INSTALLED!
Eaton Pow-R-Line C Switchboard, Front Access/Front and Rear Align, Type 3R (nonwalk-in) Flat Roof. 120/240V 1-Phase 3-Wire, 800Amp Aluminum material, Minimum Interrupt Rating: 65kA, Bus Bracing Rating: 65kA. QTY-2 400A/240V 2 Pole Chas. Mtd. FDPW Sw [R], (2) 3/0-250 kcmil, Mechanical. QTY-2 200A/240V 2 Pole Chas. Mtd. FDPB Sw [R], (1) #4-300 kcmil, Mechanical. QTY-2 200A/240V 2 Pole Chas. Mtd. FDPB Sw Provision. Additional pictures available upon request. Looking for offers.
-
80KVA MGE UPS SYSTEM WITH MAINTENANCE BYPASS AND BATTERY CABINET
MGE UPS system as follows: 80KVA UPS Model: 72-160800-44. Input: 480VAC, 3PH, 60Hz. Output: 480VAC, 3PH, 60Hz. Comes with MGE Maintenance bypass model: 72-165483-314 and MGE UPS Battery cabinet Model: 72-160250-70. Manufacture date of 2004, pulled from a working environment and is in great condition. Additional pictures available upon request. Looking for offers.
-
9800 x BK/MDL-1-16 0.25x1.25” 1/16 - 250V 900 x BK/GJV-5 3AG (axial leads)5A / 250V 325 x BK/ABC-8 3AG 8A / 250V 300 x BK/ABC-4 3AG 4A /2 50V 360 x KTK-8 5AG 8A / 600V 13300 x BK/S505-2A 5x20mm 2A / 250V 75 x BK/ABC-30 3AG 30A / 250V 75 x 35LET 17.7x56mm 35A / 250V 500 x BK/MAX-50 Auto Blade type 50A / 32V
-
GE SPECTRA SKLA36AT1200 BREAKER
240/480/600 Vac (Ul), 220 To 240/380 To 415/500/690 Vac (Iec),1200 Ampere, 3 Pole, molded case, INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC.
-
GE SPECTRA SKLA36AT0800 BREAKER
Molded case, 3 poles, 600V, 800 amperage, Bolt on connection, (LSI) Long-Time, Short-Time and Instantaneous, 65kA@480V.
-
125A TO 1200A COOPER BUSSMANN FUSES
QTY-3 COOPER BUSSMANN Fuse, RK5, FRS-R, 450A, 600VAC/300VDC QTY-3 COOPER BUSSMANN Fuse, RK5, FRS-R, 450A, 600VAC/300VDC QTY-3 COOPER BUSSMANN Fuse, 1200A, Class L, KRP-C,600VAC/300VDC QTY-3 COOPER BUSSMANN Fuse, 800A, Class L, KRP-C,600VAC/300VDC QTY-4 COOPER BUSSMANN Fuse, RK5, FRN-R, 125A, 250VAC/125VDC Looking for a partial or take all offer.
-
ServiceWire TrayCable TCNH500/2
1,032 Feet of Tray Cable by Service Wire Company P/N: TCNH500/2 - Model 500 KCMIL - 2 CDRS XHHW-2/EnviroPlus TC Zero Halogen, Limited Smoke 600 Volt Copper. Cable was purchased new and kept in dry storage. - Nominal Weight 4,196 pounds - With 110 MILS Jacket and 65 MILS Insulation - 430 AMPS - Overall Diameter 2.14 Inches - Minimum Bending Radius 13.5 Inches - Maximum AC Resistance 0.0275 OHM/MFT - Inductive Reactance 0.0252 OHM/MFT - Maximum Pulling Tension 8,000 pounds - Maximum Sidewall Pressure 500 LB/FT-RAD - Cable Capacitance 346.74 PF/FT Specification available upon request. Looking for take all offers.
-
REFURBISHED TDK INVERTERS P/N: CXA-0308
Refurbished TDK inverters P/N: CXA-0308. We understand that these go with the NEC NL6448BC33-59 LCD panels. Over 80 pieces available. Looking for offers on quantity.
-
L3 POWER MAGNETICS 29640 RECTIFIER TRANSFORMER
Features include high frequency, isolated cold water plates and water cooled conducter. Pressure drop 5 psig, working pressure 100 psg, cooling water required 70 gpm.
-
OVER 32,000 PARTS - FUSES, SWITCHES, CIRCUIT BREAKERS, AND MORE!
Click the "MORE INFO" button to view this list of over 32,000 items of fuses, breakers, switches, lugs, protection boxes, bolts, locking clips, and more from such manufacturers as Siemens, SquareD, Cooper Busman, Little Fuse, Eaton, Tyco, ZEP Solar, SMA, and many more. All NEW. Looking for offers on quantity. Minimum order values apply.
-
CARLING SWITCH CIRCUIT BREAKERS
This is a 40 amp circuit breaker kit with jumpers. 80 max volt, 50 trip amp. (150 available)
-
ALLEN BRADELY COILS AVAILABLE 80026-230-01-R
Allen Bradley 80026-230-01-R coil Contact us for all your Allen Bradley needs.
-
ASCO 7000 SERIES BYPASS ISOLATION SWITCH P/N: HO7ATBC30600C5XC
ASCO 7000 SERIES Automatic transfer & bypass isolation switch CAT# HO7ATBC30600C5XC. 600A BOM 780002, 208V 50-60Hz. Additional pictures available upon request. Looking for offers.
-
SQUARED, CUTLER HAMMER, GE, AND WESTINGHOUSE 4000 AMP CIRCUIT BREAKERS
4000 Amp 480V, 3ph circuit breakers, all new surplus or fully tested reconditioned and electrically certified: QTY-1 Square D NW40H with micro logic 6.0 reconditioned. QTY-1 Cutler Hammer Magnum MW184N, new in original crate. QTY-3 GE AK6D100 electrically operated, reconditioned. QTY-1 GE SSD 40B440 power break 2, new in factory box. QTY-1 GE TC4040TTE1CR power break 1 reconditioned. QTY-3 Westinghouse SPB100 reconditioned. Send in your requirements today.