Medical Equipment and Supplies
-
100,000 15ML MEDICINE DOSAGE CUPS
"Take your medicine" with these dosage cups. Plastohm Espagne 15ml. The little plastic cup is calibrated ; 2.5, 5.0, 7.5, 10 and 15ml. We have 100,000 available. We will sell only as the entire lot for 5 cents each.
-
MEDICAL GRADE LAPTOP CARTS FOR SALE
Medical grade laptop carts for sale , New in the box , Mobile Laptop Cart , Medical Grade . Provides a secured, all-purpose vehicle for your laptop computer, keyboard, mouse and battery. Unique Features : Height Adjustable from 29.5" to 39.5" ,Adjustable while sitting or standing , Secure mounting feature for laptops , Built-in cable management and cable storage , Medicine/Supply cabinet , Standard swivel casters (2 locking) , Powder Coat finish , Ships completely assembled . Specifications : Writing Height: Adjustable from 36" to 46" , Keyboard height: Adjustable from 29.5" to 39.5" , Writing Platform: 17"w x 15"d , Base Frame: 24"w x 24"d Cart Incldues: Keyboard tray , Dual mouse trays , Mouse storage , Lockable storage 5" swivel casters, 2 locking , Battery holder .
-
AMSCO GENERAL SURGICAL POLARIS360
AMSCO General Surgical POLARIS360 single head center pedestal mount or light with full wall control. We have 3 units available
-
COMPLETE ACUSON CARDIO/ VASCULAR ULTRASOUND SYSTEM
Complete Acuson cardio/ vascular ultrasound system.
-
ACUSAN ULTRASOUND MODEL: ASPEN.
Acusan Ultrasound Model: ASPEN. The new golden standard in echocardiography is defined by native tissue harmonic imaging (NTHI) and delta differential echo amplification--two powerfull technologies that were first introduced on Acuson's Sequoia echocardiography system. Now they migrated to the advanced system
-
SCHICK FINGER/PHALANGEAL BONE DENSITOMETRY UNIT MODEL: ACCUDEXA
Schick finger/phalangeal Bone Densitometry unit Model: ACCUDEXA
-
MIDMARK BEDS/TABLES MODEL: MIDMARKIII.
Midmark Beds/Tables Model: MIDMARKIII. Examining table/chair, hydraulic in good condition
-
ACS BAYER 180 AUTOMATED CHEMILUMINESCENCE SYSTEM
Unit is complete, in excellent condition and was last certified in April 2007. Original cost was over $40K. Open to offers. Contact Ted at 1 800 341 6468 or send and email to ted@surplustraders.net
-
PLANAR DOME PCI VID CONTROL CTX CARD
Planar Dome PCI Vid Control CTX Card. This is Planer is a medical grade. I have 1 units available. They are all new open box with warranty.
-
NEW MEDICAL EQUIPMENT FOR SALE
New medical Equipment for sale IV fuid warmers:VETONE model 102 MAXONE model 102. Made in Japan.NEW in the cases. Also,Cartrages-5000 cases. NEW. Brackets-2700 pcs.NEW. Kontrollers-2200 pcs. NEW. IV fluid Warmers-2200 units.NEW
-
JUMBO PILL BOX HOLDS A WEEK OF MEDICATION
It's BIG! 9"L x 1-7/8"W x 1"H. Imported to save you money.
-
100 "BAND-AID" TYPE STERILE PLASTIC BANDAGES
You get 100 assorted (4 sizes) sterile plastic bandages. Waterproof.
-
DELTA 3000 DEFIB/PACER/ECG ANALYZER
Delta 3000 Defib/Pacer/ECG Analyzer - Defib/AED/External Pacer/Transthoracic Pacer/ECG Analyzer (3 testers in 1 Box!) Limited quantity of these units available. The Delta 3000 combines the complete testing functions of a defibrillator tester, a pacemaker analyzer, and an ECG arrhythmia simulator into one compact, lightweight, and easy to use instrument. No other instrument delivers the performance testing power of the Delta 3000. It will test all defibrillators, all external pacemakers including transcutaneous and transvenous and all ECG equipment. The built-in user selectable test loads eliminate the need to carry extra modules to test the transcutaneous pacers. The Delta 3000 delivers unsurpassed biomedical testing capabilities in one instrument. Highlights: * Compact, Lightweight and Rugged. * Simple, Menu Driven Operation. * Large, Easy to Read Display. * Simultaneous Display of All Test Measurements. * Dedicated Print key for Immediate Documentation. * RS 232 Interface. * Battery or AC Operation. Test Functions: Defibrillator Tester: Tests All Defibrillators - Semi -Automatic, Automatic, and those with Bi-Phasic Waveforms. * Measures: Energy, Peak Voltage, Peak Current, and Cardio Sync. Time. * Storage and Playback of Output Waveforms. Pacemaker Analyzer: Tests All External Pacemakers ? Transthoracic and Transvenous Pacers. * Measures: Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refractory Periods. * 50 and 60 Hz Immunity Tests. * Transthoracic Test Load: Fixed 50 Ohm or 12 User Selectable Loads to 1000-Ohms. * A / V Pacer Test Load: 500 Ohms. ECG Simulator: Tests All ECG Equipment. * 12 lead ECG. User selectable Rates and Amplitudes. * Performance Waveforms: Sine, Square, Triangle & Pulse * 12 Arrthymia Waveforms SPECIFICATIONS: Defibrillator Analyzer: Energy Measurement: Load: 50 Ohms +/- 1% Range (High): 900 Joules, Res. 1 J. Resolution: 1 Joules Range (Low): 0 ? 100 Resolution: 0.1 Joules. Accuracy: +/- 2% of the Reading Plus 1J for Hi Range or Plus 0.5J for Low Range. Maximum voltage: 5200 Maximum Current: 100 Amp (H) Sync. Time: 0-250 ms. Waveform Output: Real Time: Output1000: 1 Stored: Discharge waveform expanded 200:1 and is repeated 8 seconds. It can be viewed through the paddles and through the ECG High Level Output. Pacemaker Analyzer: Transcutaneous: Test Load: 50 Ohms (Fixed) and Variable 100 to 1000 Ohms user selectable. Current: 1 to 200 mA Accuracy: +/- 5% +. 5 mA Pulse Width: 0.5 to 80 ms. Accuracy: +/- 1% +.1 ms. Refractory: 20 ? 500 ms Accuracy: +/- 2 % or +10ms Atrial and Ventricular: Test Load: 500 Ohms +/-1% Current: 1 to 25 mA Accuracy: +/- 5% +. 5 mA. Pulse Rate: 30 to 800 ppm. Pulse Width: 0.5 to 80 ms. Accuracy: +/- 1% +.1 ms. Refractory: 20 ? 500 ms Accuracy: +/- 2 % or +10ms Immunity Test: 50/60 Hz ECG Arrhythmia Simulator: ECG: Normal Sinus Rhythm Rate: 30, 60, 90, 120, 240 BPM Performance: Sine, Square, Triangle and Pulse Rate: 0.5 1, 2, 10, 15, 20, 25, 40 Hz. Arrhythmias: VFBC, VFBF, VTAC, AFIB, PVC, PVC1, PVC2, BGY, RBB, AFIB, ATRFT, NSR. Waveform Output: 12 Lead ECG and Paddle and HI level Output Jacks. Power Requirements: Two 9-Volt Alkaline Battery or AC adapter. Dimensions: 10 x 11 x 2.25 inches (L x W x H)(25.4 x 27.9 x 5.7 cm) Weight: 4 lbs (1.9 Kg) Accessories: Standard: AC Adapter, Universal Paddle Adapter, User Manual, Shrouded Banana Plugs (set of 2), Certificate of Calibration. Optional: Carrying Case, Paddle Adapters for various manufacturers. Please call Customer Service for part numbers.
-
DALE601 ELECTRICAL SAFETY ANALYZER
NEW UNIT comes with one-year manufacture warranty against defect and workmanship. Description The DALE601 Electrical Safety Analyzer is the industry's lowest priced full function Electrical Safety Analyzer. Unique to the DALE601 is its capability to make a broad range of external measurements. A clearly labeled single master function switch guides the user through a complete measurement procedure. The DALE601 measures Line Voltage, Instrument Current, Ground Resistance, Earth and Chassis Leakage Current, Patient Lead-to-Ground, Lead-to-Lead and Lead Isolation (M.A.P.) Current, External Gradient, Probe and Transducer Isolation Current and Point-to-Point Resistance. The device also tests all 120-volt standard wall outlets for the proper wiring. The green and an amber light indicate five normal or fault conditions. Heavy-duty switches change polarity, open and close the neutral and select Chassis or Earth Leakage Current measurements. A four-wire Kelvin bridge eliminates reading errors in resistance due to cable length and contact resistance. True RMS measurements are provided for all current readings. The AAMI test load is utilized. The DALE601 has five (5) universal EKG lead connectors that allow for any type of lead connection.There is also a single slide switch that gives the user a choice of AAMI or IEC test load. Features * Small, lightweight, self-contained portable instrument * Master range meter delivers accurate measurment for each test * Accurate test measurements with 4-wire Kelvin bridge * Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1 * Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground. * All Leakage Current measurements are displayed directly in ?Amps. * Broad range of external measurements * Five (5) Universal EKG Lead Connectors * The DALE601 is designed for 120 V operation Specifications Mains Voltage 117 Volts, 50/60 Hz Instrument Current Range: 0 - 19.99 Amps. Resolution: 10 mA Accuracy: 5 % R Ground (Earth) Resistance Range: 0 - 1.99. Accuracy: 1% R +/- 1 LSD 2 - 19.99. Accuracy: 2 % R +/- 1 LSD Resolution: 10 mOhms Leakage Current Range: 0 - 1999 ?Amp Resolution: 1 ?Amp Accuracy: 1% R +/- 1 LSD Frequency: DC & 25 Hz - 1kHz: 1.0% R 1KHz - 100 KHz: 2.5% R 100 KHz - 1 MHz: 5% R Controls 1. Function Switch - 9 position rotary 2. Lead Switch - 6 position rotary 3. Neutral Switch - 2 position rocker (Open/Closed) 4. Polarity Switch - 3 position rocker (Normal/Off/Reversed) 5. Leakage Switch - 2 position rocker (Chassis/Earth) DUT Power 117 VAC, 16 Amps@ 120 V, 10 Amps @ 230 V Physical Size: 4.0 x 7.8 x 1.6 inches (102 x 196 x 41 mm)
-
ECC X-RAY PULSE COUNTER / EXPOSURE TIME METER
ECC X-Ray Pulse Counter / Exposure Time Meter NEW" X-ray Pulse Counter Model 8700 WARRANTY: 2-year manufacturer warranty ACCESSORIES: Operator manual, Calibration Certificate TYPICAL SALES LEAD TIME: 7-10 Business days Optional Accessories: 8700CC Carrying Case for Model 8700 - Padded Cordura: $45.00 8700RS Remote Sensor allowing operation of the pulse counter up to 10 feet from the X-Ray Head. This small weighted sensor sits under x-ray head with a cable that plugs into the 8700: $70.00 8700SC Oscilloscope cable that connects "Scope" output of the model 8700 to standard BNC oscilloscope input: $30.00 DESCRIPTION The Model 8700 X-Ray Pulse Counter/ Exposure Time Meter is used to measure the time or duration of radiation output produced by a wide variety of x-ray generators. The x-ray sensor in the 8700 allows direct measurement of exposure from the x-ray head. Pulses produced by half wave and full- wave x-ray are measured as 60 or 120 pulses per second. For DC, capacitor discharge and 3-phase x-ray, the 8700 measures the exposure time in milliseconds. When testing x-ray timers and controls, the time of relay contact can be measured using the AC input feature. The Model 8700 is "self-resetting". There is no need to reset the instrument after each reading. The reading is stored after each exposure, holding until the next exposure. RECENT IMPROVEMENTS Wider Range Increased sensitivity allows use with lower power x-rays Wider dynamic range allows use with higher power x-rays More accuracy on DC/Multiphase high power x-rays Measurement ends at 70% of peak value eliminating inaccuracy due to slow tail. Periodic calibration is not needed Digital / microprocessor circuitry does not drift or lose accuracy over time. New circuitry saves production time and parts cost, allowing us to keep our competitive prices. Low power circuitry improves battery life. FEATURES Small Hand Held Size AC or DC X-Rays New High Accuracy Circuit Self Resetting Battery Operated Two Year Warranty Direct Exposure Reading or AC Input Use for Medical or Dental X-Rays Remote Sensor Option No Periodic Calibration Needed Custom Carrying Case Option Durable ABS Plastic Case TYPICAL APPLICATIONS Measurement of Exposure Quality Assurance Verification of X-ray Exposure Time Calibration of X-ray Timer Direct Measurement of Timer Accuracy Troubleshooting and Repair of x-ray SPECIFICATIONS ACCURACY AC - one count DC- 2% +/-1 millisecond SENSITIVITY X-ray input: 40kVp, 5mA at 5 cm from top surface of case, pointed to target AC Input: 90 VAC minimum RANGE 9999 Pulses 9999 Milliseconds DISPLAY 0.4" Liquid Crystal POWER Internal 9 Volt Battery Low Battery Indicator BATTERY LIFE 48 hours continuous Typically 9 months of normal use CONTROLS/ INDICATORS Three position switch Pulse Off Milliseconds 4 digit liquid crystal display 0.4" characters Low battery indicator Oscilloscope output Remote Sensor Input PHYSICAL SIZE 80 x147x 40mm 3.15 x 5.8 x1.6 inches CONNECTIONS None required for direct exposure measurement 2 tip jacks for AC input Jack for Remote Sensor Option Jack for Oscilloscope Output OPTIONAL ACCESSORIES Remote sensor with 3 meter cable Padded Cordura Carrying Case Oscilloscope Interface Cable Long Life Battery
-
NETECH DELTA 2000 DEFIBRILLATOR ANALYZER INCLUDING AED'S
NETECH Delta 2000 Defibrillator Analyzer including AED's WARRANTY: One-year Manufacturer Warranty ACCESSORIES: Calibration Certificate, Operator Manual DELTA 2000 Defibrillator Analyzer DELTA 2000 is a full function defibrillator analyzer designed to test all Bi-Phasic defibrillators including semi and automated external Defibrillators (AED). The built in ECG and arrhythmia waveforms makes it easier than ever to test the new automated defibrillators. Input jack is provided for external arrhythmia waveforms. It is compact, rugged and light-weight and costs fraction of our competitions units. FEATURES: Tests Bi-Phasic Defibrillators. Tests all AEDs. Large LCD display. Compact and easy to use Built-in arrhythmia Waveforms. Built-in ECG waveform.Internal paddle adapters. Battery or AC powered.Battery or AC powered SPECIFICATIONS Energy Measurement: Load: 50 Ohms +/- 1% Resolution: High Range: 1 Joule Low Range: 0.1 Joule Accuracy: High Range: +/- 2% of Reading +/- 1 Joules Low Range: +/- 2% of Reading +/- 0.1 Joule Sync Time: 0 - 250 ms Pulse width 0 - 60 ms Waveform Simulation: ECG @ 60 BPM and 90 BPM VFIB and VTAC. External Arrhythmia input. Waveform Output/Input: ECG High Level Output. 1/4 Phone Jack External Arrhythmia input jack. 1/4 Phone Jack Real time Waveform output. 1/4 Phone Jack Defibrillator discharge waveform (expanded 200:1) is played back through the paddle and the output Phone Jack for recording. Physical: Display: 4 Digit LCD Dimensions: 10.4 x 7.2 X 4.0 Power: 9 Volt Alkaline or AC adapter Weight: 3 lbs (1.36Kg) Optional Adapters: Paddle adapter sets are available for AEDs.
-
ULTRASOUND POWER METER UPM DT100AV
Ultrasound Power Meter UPM DT100AV **New** All products manufactured by Ohmic Co. are warranted to be free of defects in material and workmanship for one year after delivery. Any equipment found to be defective within this period will be repaired or replaced free of charge. Specifications: Power Range: 0.1 to 30 Watts Resolution: +/-200 mW, +/- 0.01gram, +/-1 count Display: 3-digit LCD, 1.3" H Operating Temp: 10-40 degrees C Accuracy: +/-3% @ 10 Watts Stabilization: 2.5 Second Integration Maximum Weight Capacity: 410 Grams Maximum Transducer Size: 3" Diameter Transducer Operating Frequency: 1-10MHz Test Media: Degassed Water Data Output: Bi-Directional RS-232 Power: 12Vac, 1 Amp 120VAC Adaptor Supplied(adaptors for 240vac available on special order: 120vac to 12vac EMI Rating: Conforms to CE Electrical Safety: Conforms to CSA Size: 8"H x 12" L x 8.75" W Weight: 11 Lbs Net Carrying Case: Black Anodized Aluminum
-
Biotek Digital Pressure Meter Digital Pressure Meter WARRANTY: 6 months CALIBRATION: Will come with a current calibration certificate Reliable and accurate measurement of gas or liquid pressures. The Biotek DPM Universal Pressure Meter measures positive or negative pressures. Use a single mode switch to select one of five ranges. An LCD readout displays pressures received externally from the following sources: Ophthalmologic lasers, dialysis machines, automatic tourniquets, drainage devices, IV pumps, diagnostic and surgical suction devices, ventilators, and pressure gauges. FEATURES: *Handheld use *Air and Liquid measurements *Multiple Ranges SPECIFICATIONS: Range: -700 to +800 mmHg -952 to +1088 cm H2O -374 to +428 in of H2O -13.50 to +15.0 psi -13.5 to 75.0 psi Accuracy: +/- 1 % of full scale Pressure Connector: Male luer lock Overpressure Protection: 110psi Power: 9 V alkaline battery Dimensions: 5.75" L x 3.125" W x 2.5" H (15cm L x 8cm W x 6cm H) Weight: 10.4oz (295g)
-
BIOTEK IDA-2 INFUSION DEVICE ANALYZER
Biotek IDA-2 Infusion Device Analyzer This portable device quickly evaluates the operation of infusion devices with both steady and nonsteady flow patterns. A simple user interface removes the clutter form infusion pump testing. Use the instrument in manual or computer control modes. MODES OF OPERATION: Steady Flow: This mode performs direct flow measurement by timing the displacement of fluid within a known volume. Use this mode for testing devices that have steady flow patterns, such as a syringe driver. The sample size varies with the flow rate, to minimize the time to first reading. NonSteady Flow: This mode performs a volume measurement and derives the flow. This sample size is set at 1ml regardless of the flow rate. Use this mode to test infusion pumps with nonsteady flows and PCA's. Occlusion Pressure: Set the infusion pump to the manufacturer's recommended flow rate, and select occlusion on the Biotek IDA-2. Measurements will be displayed in mmHg or PSI. This measures the downstream occlusion on the infusion pump. Priming: Priming the Biotek IDA-2 is a simple technique using an enclosed syringe. Generally this talk ccan be done with less than 5ml of fluid, depending on the priming solution. FEATURES: --Quick, accurate measurements of steady and nonsteady flow devices --Flow-rate, delivered-volume, and occlusion-pressure testing --Portable (attaches on an IV-Pole). --Simple setup and operation --RS232/Printer ports STANDARD ACCESSORIES: Operating Manual Drain Tubes Stopcocks Priming Syringe SPECIFICATIONS: Flow Rate: 1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy) 100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy) 1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy) Volume: 1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy) 100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy) 1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy) Occlusion: 0 to 35 PSI +/-5% of reading Time to Perform Flow-Rate Measurement: 1ml/hr: 5min (normal), 60min (high accuracy) 100ml/hr: 25 sec (normal), 60 sec (high accuracy) 1000ml/hr: 5 sec (normal), 5 sec (high accuracy) Power: Operating Voltage (frequency): 115/230 VAC, switchable (50-60Hz) Dimensions: 6.25" L x 9.75" W x 5.25" H (16cm L x 25cm W x 13cm H) Weight: 5lbs (2.3kg)
-
SPACELABS MEDICAL 90309 PORTABLE PATIENT MONITOR
Spacelabs Medical 90309 Portable Patient Monitor Accessories: ECG Cable/Leads, NIBP Hose/Adult Cuff, SPO2 interface cable/sensor, 90470 ECG Module/2BP/2 Temp, 90351 Bottom Slice NIBP/SPo2. Parameters: ECG/Resp/2BP/2Temp/NIBP/SP02 Warranty: 6-month warranty, biomedically certified.
-
CRITIKON COMPATIBLE DUAL LUMEN NIBP HOSE
Critikon Compatible Dual Lumen NIBP Hose ompatible with the following manufacturers: Dinamap 1846, 8100, 9300,Plus Series Monitors, Also Kontron, Mennen, Invivo, Nihon Kohden, and MDE Call now to place your order.
-
LKG 601 ELECTRICAL SAFETY ANALYZER LKG601
LKG 601 Electrical Safety Analyzer LKG601 The LKG 601, Electrical Safety Analyzer is an extremely easy to use portable Electrical Safety Analyzer designed specifically for testing non-ECG equipment. Ground resistance, leakage current, and instrument current test measurements are displayed on its large LCD. FEATURES: * Easy to Use * Large LCD Display * Accessible Line Fuse * Calibrated Test Points * Selectable Test Loads * 15 and 20 Amp Capability * Point-to-Point Testing * Use any Test Cable * 10 Lead Universal Connector * Complies with AAMI/ESI 1993 * LED Unit of Measure Indicator Measurements: * Line Voltage * Cord Resistance * Case Leakage Current * Earth Leakage Current * Leads Leakage Current * Leads ISO Test * Instrument Current * Point-to-Point Measurement Specifications: Display: 3 Digit LCD Display Power Requirements: 110V AC 50 - 60 Hz, 15 amps 220V AC, 50 - 60 Hz, 10 amps Physical Dimensions: 5.5 x 3.25 x 2.5 inches


