BIOTEK IDA-2 INFUSION DEVICE ANALYZER
- Product SKU: WB437
- Product Name: BIOTEK IDA-2 INFUSION DEVICE ANALYZER
- Manufacturer: -ASSORTED
Biotek IDA-2 Infusion Device Analyzer This portable device quickly evaluates the operation of infusion devices with both steady and nonsteady flow patterns. A simple user interface removes the clutter form infusion pump testing. Use the instrument in manual or computer control modes. MODES OF OPERATION: Steady Flow: This mode performs direct flow measurement by timing the displacement of fluid within a known volume. Use this mode for testing devices that have steady flow patterns, such as a syringe driver. The sample size varies with the flow rate, to minimize the time to first reading. NonSteady Flow: This mode performs a volume measurement and derives the flow. This sample size is set at 1ml regardless of the flow rate. Use this mode to test infusion pumps with nonsteady flows and PCA's. Occlusion Pressure: Set the infusion pump to the manufacturer's recommended flow rate, and select occlusion on the Biotek IDA-2. Measurements will be displayed in mmHg or PSI. This measures the downstream occlusion on the infusion pump. Priming: Priming the Biotek IDA-2 is a simple technique using an enclosed syringe. Generally this talk ccan be done with less than 5ml of fluid, depending on the priming solution. FEATURES: --Quick, accurate measurements of steady and nonsteady flow devices --Flow-rate, delivered-volume, and occlusion-pressure testing --Portable (attaches on an IV-Pole). --Simple setup and operation --RS232/Printer ports STANDARD ACCESSORIES: Operating Manual Drain Tubes Stopcocks Priming Syringe SPECIFICATIONS: Flow Rate: 1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy) 100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy) 1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy) Volume: 1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy) 100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy) 1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy) Occlusion: 0 to 35 PSI +/-5% of reading Time to Perform Flow-Rate Measurement: 1ml/hr: 5min (normal), 60min (high accuracy) 100ml/hr: 25 sec (normal), 60 sec (high accuracy) 1000ml/hr: 5 sec (normal), 5 sec (high accuracy) Power: Operating Voltage (frequency): 115/230 VAC, switchable (50-60Hz) Dimensions: 6.25" L x 9.75" W x 5.25" H (16cm L x 25cm W x 13cm H) Weight: 5lbs (2.3kg)
- Product Availability: Available
- Product SKU: WB437
- Product Name: BIOTEK IDA-2 INFUSION DEVICE ANALYZER
- Manufacturer: -ASSORTED
Biotek IDA-2 Infusion Device Analyzer This portable device quickly evaluates the operation of infusion devices with both steady and nonsteady flow patterns. A simple user interface removes the clutter form infusion pump testing. Use the instrument in manual or computer control modes. MODES OF OPERATION: Steady Flow: This mode performs direct flow measurement by timing the displacement of fluid within a known volume. Use this mode for testing devices that have steady flow patterns, such as a syringe driver. The sample size varies with the flow rate, to minimize the time to first reading. NonSteady Flow: This mode performs a volume measurement and derives the flow. This sample size is set at 1ml regardless of the flow rate. Use this mode to test infusion pumps with nonsteady flows and PCA's. Occlusion Pressure: Set the infusion pump to the manufacturer's recommended flow rate, and select occlusion on the Biotek IDA-2. Measurements will be displayed in mmHg or PSI. This measures the downstream occlusion on the infusion pump. Priming: Priming the Biotek IDA-2 is a simple technique using an enclosed syringe. Generally this talk ccan be done with less than 5ml of fluid, depending on the priming solution. FEATURES: --Quick, accurate measurements of steady and nonsteady flow devices --Flow-rate, delivered-volume, and occlusion-pressure testing --Portable (attaches on an IV-Pole). --Simple setup and operation --RS232/Printer ports STANDARD ACCESSORIES: Operating Manual Drain Tubes Stopcocks Priming Syringe SPECIFICATIONS: Flow Rate: 1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy) 100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy) 1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy) Volume: 1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy) 100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy) 1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy) Occlusion: 0 to 35 PSI +/-5% of reading Time to Perform Flow-Rate Measurement: 1ml/hr: 5min (normal), 60min (high accuracy) 100ml/hr: 25 sec (normal), 60 sec (high accuracy) 1000ml/hr: 5 sec (normal), 5 sec (high accuracy) Power: Operating Voltage (frequency): 115/230 VAC, switchable (50-60Hz) Dimensions: 6.25" L x 9.75" W x 5.25" H (16cm L x 25cm W x 13cm H) Weight: 5lbs (2.3kg)

