EXCESS ELECTRICAL INVENTORY FOR SALE
Click on the MORE INFO button to see the list of electrical items for sale as a complete lot only. VA019.

For additional information contact John by phone
at 514-685-9881 or by email directly at john@surplustraders.net
Please make sure to quote our list number VA019 in all correspondence.
Item DescriptionQty
2594 PLUG, CONTROL STATION -MADE BY MARINCO PART NUMBER 2021C, 20 amps LOCKING 135
0351A00314554XX DIRECTIONAL OVERCURRENT RELAY, SEL-351A, HORIZOTAL PANEL MOUNTED, 125 VDC, 5A PHASE AND NEUTRAL CURRENTS, STANDARD PROTOCOL 2
100311-01-02-24 MANUAL TRANSFER SWITCH, ASCO-2 POLE, 100A, 480VAC, 60HZ, 7000 SERIES, NEMA 1 WITH STANDARD FEATURES. 1
100392-0105-01A 125VDC BATTERY SYSTEM1
100692-0104-03 HINDLE, BATTERY CHARGER -P/N: AT10-130-050-240-2-1-1-1-1-3-0-1-0-0
DIM: 37.95"H X 20.9"W X 70.87"H
WEIGHT: 440 LBS
WITH STANDAR FEATURES AND FOLLOWING OPTIONS:
AC & DC CIRCUIT BREAKERS AND FUSES
AUXILIARY ALARM BOARD
LIGHTING ARRESTOR
2
100876-06-01-1A AUTOMATIC TRANSFER SWITCH, ASCO -SERIES 4000, MODEL: D04ATSA30150C50C, 3 PHASE, SOLID NEUTRAL, 150A, 208VAC, NEMA 1 ENCLOSURE 1
101491-01-01-20 PANALARM, SERIES 90 -ANNUNCIATOR CONSISTING OF THE FOLLOWING:
1) MODEL 94CAS34 CABINET 3 ROWS HIGH BY 4 COLUMNS WIDE
1) MODEL 90SM34 SURFACE MOUNT ENCLOSURE, NEMA 12
12) MODEL 92LA01 DUAL WINDOW LIGHT-BOXES
24) MODEL 92NP1WH ENGRAVED/BLANK NAMEPLATES
24) MODEL 91TF1T24DC4CE5CR4EM ALARM CARDS, SEQUENCE TFS, 24 VOLTS
1) MODEL 90F1X1PB FLASHER CARD (POS. 3-4-D)
1) MODEL: 90P2X120AC24FC 450W, MTD & WIRED POWER SUPPLY, 120VAC
1) MODEL 90AX1 AUX. RELAY CARD, IN REQ’D WB-3 WIREBOX
1) MODEL NT2-24DF DOOR MOUNTED HORN
1) MODEL SW102A DOOR MOUNTED PUSHBUTTON (ACK)
1) MODEL SW102T DOOR MOUNTED PUSHBUTTON (TEST)
1) MODEL SW102FT DOOR MOUNTED PUSHBUTTON (FIRST RESET)
1) MODEL 90RFR2X17FTD1CE REFLASH OUTPUT CARD (POS. 3-4-B)
NO BATTERY BACKUP INCLUDED.
2
11183-02-01 BATTERY CHARGER, HINDLE -MODEL AT10-130-25F, 130VDC,25A OUTPUT,480VAC SINGLE PHASE INPUT, FILTERED BATTERY CHAR- GERS, COMPLETE WITH ALL STANDARD FEATURES, PLUS THE FOLLOWING: SPACE HEATER, AUX. TB, TEM- PERATURE COMPENSATION 1
11203-01-47 WESCO INDUSTRIAL LIFTING - PLATFORM, 750LB CAPACITY WESCO PART NUMBER DPL-54-2222, GRAINGER PART NUMBER 3W220. 1
12SLA50/10BLOC 50AH ALCAD BAT 125VDC - MONOLITE VR LEAD ACID, 10 BLOC,CONNECTORS GREASE, WRENCH, 2 END LUGS, MSDS, I/B, FLAME RET VENTS, CELL NOS 1
3A73950G02 CIRCUIT BREAKER, C-H, VCP-W - 15KV,1200A,500MVA, 23KA INTERRUPTING, 125VDC CNTRL VOLTAGE FOR CLOSE,CHARGE AND TRIP. 5
42100-P6 PORCELAIN BUS SUPPORT - 3/4" x 4" BAR CLEAR GLAZED 63
6510C91G03 WESTINGHOUSE VCP-W MINI -MODULE, 1200A UPPER GLASS POLYESTER INSULATING TUBES FOR 5KV & 15KV USE. 1
66A5092G02 6 STUD 1200A/2000A MAN-UALLY OPERATED GROUND AND TEST DEVICE FOR VCP/W BREAKER 1
A48H4812 ENCLOSURE - BOX A48H4812WFSSLP3PT HOFFMAN1
AT101300120112000 ALCAD BAT CHARGER - INPUT: 120/208/240VAC 1PH 60HZ, OUTPUT: 130VDC 12A, W/OPTIONS: FILTERED, PRIMARY Type=120/208/240VAC ALARM BOARD, SHIP DIRECT TO CUSTOMER 1
ATH3FDA20030AKU CUTLER HAMMER AUTOMATIC -TRANSFER SWITCH. HORIZONTAL MOUNT, ATC-300 CONTROLLER,HFD, FIXED MOUNT 2 POLES, 30A, 120VAC,60HZ OPEN ENCLOSURE.UL LISTED 1
BE1-25M1EA6PN4N0F RELAY SYNC CHECK BE1-25 - BASLER 1PH VOLTAGE SENSG 120VAC 1-99 DEG PH ANGLE, N/O OUTPUT CONTACT,0.1- 99SEC. PWR SUP,125VDC OR 100/120VAC. TARGET,. CURRENT OPERATED. OPTION 1; NON-ISOLATED CONTACT SENSING INPUT; OFTION 2: NONE; OPTION 3: NONE; MOUNTING: SEMI-FLUSH. 1
CS14HR-SC-24VDC FIBER CONVERTER / HESCO - HARDENED FACTORY FLOOR RATED FIBER CONVERTER WITH SC AND BUILT-IN SCREW TERMINALS FOR 24VDC - DIN RAIL MOUNTING. 1
F60-K03-HLH-F8L-H6L-MXX-PXX-UXX-WRH GE/UR RELAY MODEL F60 FEEDER MGT RELAY -IN 19" RACK FOR HORIZONTAL MOUNTING AND INCLUDES THE FOLLOWING:
- BASE UNIT, RS-485 AND MULTI-MODE ST REDUNDANT 100BASE-FX, SOFTWARE: IEC-61850, HORIZONTAL
(19" RACK), ENHANCED FRONT PANEL WITH ENGLISH DISPLAY AND USER PROGRAMMABLE PUSHBUTTONS
, MODULE F FOR STANDARD 4CT/4VT WITH ENHANCED DIAGNOSTIC, MODULE H WITH 2 FORM A (CURRENT
WITH OPTIONAL VOLTAGE) AND 2 FORM C OUTPUTS, 8 DIGITAL INPUTS, NO MODULE M, NO MODULE P, NO
MODULE U, POWER SUPPLY : 125/250V AC/DC WITH REDUNDANT 125/250 V AC/DC POWER SUPPLY.
12
P21518133234200000A BREAKER/ C-H DSL11-620 - EO/DO, 2000AF, DIGITRIP 510 W/LT,ST & 3WGF,2000A SENSORS & RATING PLUG, 50HZ, 3000A LIMITERS, 125VDC CLOSE & TRIP, 5-NO & 5-NC AUX CONTACTS, WIRED PER FIGS A1,F3,D0, B1,E1, UL LABEL 1
RMDTDR-8EQ ALCAD BATTERY RACK - SEISMIC, 2 ROW, 2 TIER, 8’ LONG 1
S205G066XXXX MVS - C LBS. C-H 5KV, 3PH - 600A CONT/INTERRUPTING, 61KA MOM/FAULT CLOSE, W/GLASSPOLY. INSULATORS 1
SEL-0351S713B455421 PROTECTION AND BREAKER CONTROL RELAY -SEL RELAY MODEL SEL-351S:
-FIRMWARE STANDARD PLUS MIRRORED BITS, LOAD PROFILE,
POWER ELEMENTS,VOLTAGE SAG/SWELL/INTERRUPTION.
-I/O BOARD ADDITION 12 STD OUPUTS, 8 INPUTS, 3U.
-MOUNTING HORIZONTAL PANEL MOUNT.
-USER INTERFACE AUXILARY TRIP/CLOSE PB W/ GUARDS, CONFIGURABLE LABELS.
-POWER SUPPLY 125/250VDC OR VAC.
-SECONDARY VOLTAGE INPUT WYE-CONNECTED OR DELTA-CONNECTED Vab AND Vbc (300V MAX).
-SECONDARY INPUT CURRENT 5A PHASE AND 5A NEUTRAL.
-CONTROL INPUT VOLTAGE 125VDC.
-COMMUNICATION PROTOCOL STANDARD PLUS DNP 3.00 LEVEL 2 SLAVE.
12
SEL-0387503X53XX4X1 CURRENT DIFFERENTIAL OVERCURRENT RELAY/SEL MODEL SEL-387, STANDARD FIRMWARE PLUS INTEGRATION ENHANCEMENTS WITH BINARY SER, 2U HORIZONTAL PANEL MOUNT,48/125VDC OR 120VAC POWER SUPPLY, SECONDARY INPUT CURRENT 5A PHASE, 125VDC CONT.INPUT VOLTAGE COMMUNICATION PROTOCOL DNP 3.0 LEVEL 2 SLAVE. 3
SEL-071001ABA0X7185000 SEL-710 MOTOR PROTECTION RELAY - 110-250 Vdc, 110-230 Vac, 50/60 Hz,
125 Vdc/Vac Digital Input (2DI / 3DO), IRIG-B Input,
EIA-232 Front / EIA-232 Rear,
Additional 3DI / 4DO / 1 AO (125 Vdc/Vac),
AC Voltage Input (300 Vac max),
5A PHASE 5A NEUTRAL CURRENT Input,
No Conformal Coating Circuit Board.
5
SFL64-30SX-SPEC LIFT TRUCK WESCO TYPE-S - SIMILAR TO MODEL SFL-64- 30SX EXCEPT LIFT PLATE TO BE PREPUNCHED FOR POWELL P/N 77902H01 3
UE3G2L036C61T TOSHIBA UPS 3.6 KVA - 1600 SERIES, 208/240V 50/60HZ INPUT, 30A INTERNAL BREAKER, 208/240/120V 50/60HZ OUTPUT, 15A RATED CURRENT, HARDWIRE 1
WS2FBZGQEXBCXXX BREAKER/GE WPH-16, 1600AF- 3P, EO/DO, 800A SENSORS, 800A RATING PLUG, 65KA INTERRUPTING RATING, MICRO- VERSA TRIP/M WITH LT,ST, INST, SWITCHABLE ST OR INST, 125VDC CLOSE & TRIP, 5-NO & 5-NC AUX CONTACTS, W/ PUSH BUTTON COVER, UL LABEL 3
WS2GBZMQEXBCXXX BREAKER / GE WPH-16, 1600AF - 3P, EO/DO, 1600A SENSORS, 1600A RATING PLUG, 65KA INTERRUPTING RATING, MICRO- VERSA TRIP/M WITH LT,ST, INST, SWITCHABLE ST OR INST, 125VDC CLOSE & TRIP, 5-NO & 5-NC AUX CONTACTS, W/ PUSH BUTTON COVER, UL LABEL 4
WS3DBBGFEXBBXXX BREAKER / GE WPX - 08 800AF - 3P, EO/DO, 800A SENSORS, 800A RATING PLUG, 65KA, MICRO-VERSA TRIP M W/LT, ST,3WGF. 125VAC CLOSE AND 125VDC TRIP, 5-NO & 5-NC AUX CONTACTS, 2-FORM C BELL ALARM CONTACTS W/LOCKOUT. 6
WS3DBRGQEXABXXX BREAKER / GE WPX-08, 800AF - 3P, EO/DO, 800A SENSORS, 800A RATING PLUG, 65KA, MICRO-VERSA TRIP M W/LT, ST,INST,& 3WGF W/ SWITCHABLE ST OR INST AND GF. 125VDC CLOSE AND TRIP, 2-NO & 2-NC AUX CONTACTS, (2) FORM C BELL ALARM CONTACTS W/LOCKOUT. 1
WS3DBZAQEXBCXXX BREAKER / GE WPX- 08, 800AF -3P, EO/DO, 800A SENSORS, 400A RATING PLUG, 65KA INTERRUPTING RATING, MVT-M W/ LT, ST, INST, SWITCHABLE ST OR INST, 125VDC CLOSE & TRIP, 5-NO & 5-NC AUX CONTACTS, W/ PUSH BUTTON COVER, UL LABEL. 2
WS3DBZGQEXBCXXX BREAKER / GE WPX - 08 800AF - 3P, EO/DO, 800A SENSORS, 800A RATING PLUG, 65KA INTERRUPTING RATING, MVT-M W/ LT, ST, INST, SWITCHABLE ST OR INST, 125VDC CLOSE & TRIP, 5-NO & 5-NC AUX CONTACTS, W/ PUSH BUTTON COVER, UL LABEL. 2
WS3DCAGXXXABXBX BREAKER / GE, WPX -08 800AF - 3P, MO/DO, 800A SENSORS, 800A RATING PLUG, MICROVERSA TRIP PM W/ LT,ST, 2-NO & 2-NC AUX CONTACTS, 2-NO & 2-NC BELL ALARM CONTACTS W/ LOCKOUT, OPERATIONS COUNTER, UL LABEL 4
WSMGAAMXXXABXXX BREAKER / GE, WPF-16, 1600AF - 3P, MO/DO, 2500A CLASS L FUSES, 1600A SENSORS , 1600A RATING PLUG, MICRO-VERSATRIP PLUS W/ LT, ST, 3-NO & 3-NC AUX CONTACTS, 2-NO & 2-NC BELL ALARM CONTACTS W/ LOCKOUT, UL LABEL 4
WSMGABMXXXABXXX BREAKER / GE, WPF-16 1600AF - 3P, MO/DO, 2500A CLASS L FUSES, 1600A SENSORS , 1600A RATING PLUG, MICRO-VERSATRIP PLUS W/ LT, ST, GF, 3-NO & 3-NC AUX CONTACTS, 2-NO & 2-NC BELL ALARM CONTACTS W/ LOCKOUT, UL LABEL 3
For additional information contact John by phone
at 514-685-9881 or by email directly at john@surplustraders.net.
Please make sure to quote our list number VA019 in all correspondence.