105MW GENERAL ELECTRIC STEAM TURBINE GENERATOR
GE tandem-compound turbine is designed for utility application and is well suited for conventional, biomass and combined cycle integration. Hydrogen-cooled Generator is completely enclosed with hydrogen as the cooling medium. Specs from name plate as follows:
ˇ105 MW, Straight Condensing, Double Flow Steam Turbine (SCDF 2 x 23)
ˇRating: 105,334 KW; 3600RPM
ˇSteam Conditions:
ˇInitial Pressure: 1250 psig
ˇInitial Temperature: 950 FFT
ˇInlet Steam Flow: 906,167 lbs/hr
ˇBack Pressure: 3.0 inches Hg Abs
ˇUncontrolled Extractions: 7
ˇStages: 18
2,000 hours since installation. Unit has been inspected and certified by the OEM as well as a major turbo machinery manufacturer and results concluded it can be returned to "as new" specifications and is capable of performing at original name plate output on a long term basis. Click "more info" for additional photos. GF803.

For additional information contact Patrick by phone
at 450-902-0491 or by email directly at patrick@surplustraders.net
Please make sure to quote our list number GF803 in all correspondence.
For additional information contact Patrick by phone
at 450-902-0491 or by email directly at patrick@surplustraders.net.
Please make sure to quote our list number GF803 in all correspondence.